MG Co.,Ltd. – Track/Holding (M2AMS-AA-M2/UL)

Manufactured:  MG Co.,Ltd. (M System)

Product:  Track/Holding

Model:  M2AMS-AA-M2/UL

 

General Information

Super-Mini Signal Conditioners Mini-M Series

 

Functions & Features

  • Track mode:  The output follows proportionally to the input
  • Hold mode:  The output at the point of command is held until the command is reset
  • External:  Contact closure as the commands

 

Typical Application

  • Capturing dignals from a compossite analyzer performing on each sample in turn.

 

General Specifications

  • Construction:  Plug-in
  • Connection:  M3 screw terminals (torque 0.8 Nm)
  • Screw terminal:  Chromated steel (Standard) or stainless steel
  • Housing material:  Flame-resistant resin (black)
  • Isolation:  Input to output to power
  • Overrange output:  Approx. -10 to +120% at 1-5 V
  • Zero adjustment:  -5 to +5% (front)
  • Span adjustment:  95 to 105% (front)
  • Hold control:  Hold when opening the terminals 5-8; tracks when closing them

Input Specifications

DC Current 

  • Shunt resistor attached to the input terminals (0.5 W)
  • Specify input resistance value for code Z.

DC Voltage:  -300 – +300 V DC

  • Minimum span:  3 mV
  • Offset:  Max. 1.5 times span
  • Input Resistance

         > Span 3 – 10 mV : ≥ 10 kΩ

         > Span 10 – 100 mV : ≥ 10 kΩ

         > Span 0.1 – 1 V : ≥ 100 kΩ

         > Span ≥ 1 V : ≥ 1 MΩ

Hold Control

  • Contact rating:  5 V @1 mA
  • Detection levels:  ≤ 1.25 kΩ / 1  V at  Track  ≥ 20 kΩ / 4 V at Hold

 

Output Specifications

DC Current: 0-20 mA DC

  • Minimum span:  1 mA
  • Offset:  Max. 1.5 times span
  • Load resistance:  Output drive 15 V max.

DC Voltage:  -10 – +12 V DC

  • Minimum span: 5 mV
  • Offset:  Max. 1.5 times span
  • Load resistance:  Output drive 1 mA max.; at ≥ 0. V