คำอธิบาย

Product detail:

Without the fluid coupling, the motor instantly transmits its locked rotor torque (starting

torque) to the driven machine (point A at right). Then, it quickly reaches and applies

the breakdown torque (point B). For common applications, locked rotor and breakdown

torque often approximates 200% or more of the motor nameplate rating.

Damage can result if the required break-away starting torque of the driven machine is

significantly less, because the machine will be abruptly accelerated to rated speed.

With a fluid coupling installed, however, the torque to the driven machine starts at zero

(Point C) and gradually increases as the coupling impeller accelerates to point D.

When the output torque of the fluid coupling exceeds the break-away starting torque of

the driven machine (point D), the driven machinery gradually accelerates (right half of

chart). As the machine comes up to rated speed, the slip of the fluid coupling decreases

to (point E) and uniform power is transmitted at maximum efficiency.

Features & Benefits:

  • Up to 7 inches (177 mm) bore capacity
  • Up to 1,500 hp (1,119 kW) power rating
  • Up to 66,000 in-lb (7,367 Nm) torque capacity
  • Overload protection
  • Starting power adjustable from 120 – 250% of full torque load torque

 

 ,,,#TRUE TORQUE FLUID COUPLINGS