CHINT (MCB) – Modular Din Rail Products
- Description
Description
CHINT (MCB) – Modular Din Rail Products
NB1-63(H) Miniature Circuit Breaker
General
▪ Short circuit protection
▪ Overload protection
▪ Switch
▪ Isolation
▪ Contact position indicator
▪ Advanced current-limit technology
▪ Heat dissipation gap for better cooling
▪ Extendable DIN-rail holder for easy installation
NB1-63G Miniature Circuit Breaker
General
▪ Short circuit protection
▪ Overload protection
▪ Switch
▪ Isolation
▪ Various wiring solutions: U-type/pin-type/Comb-type Busbar/Cable
NBH8 Miniature Circuit Breaker
General
▪ Short circuit protection
▪ Overload protection
▪ Switch
▪ Isolation
▪ 1P+N in one module.
▪ Contact position indicator
NXB-80 Miniature Circuit Breaker
General
▪ Compliant standards: IEC60898-1
▪ Rated current: 80A
▪ Rated voltage: 240/415V
▪ Frequency: 50/60Hz
▪ Electromagnetic release type: B, C, D
▪ Number of poles: 1P, 1P+N, 2P
▪ Mechanical life: 20000 cycles
▪ Electrical life: 10000 cycles
▪ Rated short-circuit breaking capacity: 6KA
▪ Short-circuit breaking capacity: 6KA
▪ Rated impulse withstand voltage (Uimp): 4kV
▪ Protection of circuits against short-circuit currents, overload currents, switch, isolation
NB8-63
General
1.1 Function : protection of circuits against short-circuit currents, protection of circuits against overload currents, switch,
isolation. NB8 -63 circuit-breakers are used in domestic installation, as well as in commercial and industry electrical distribution systems.
1.2 Selection : Technical data of the network at the point considered: short-circuit current at the circuit-breaker installation point, which must always be less than the breaking capacity of this device, network normal voltage.
Tripping curves:
B curve (3-5In) protection for people and big length cables in TN and IT systems.
C curve (5-10In) protection for resistive and inductive loads with low inrush current.
D curve(10-16In) protection for circuits which supply loads with high inrush current at the circuit closing (LV/LV transformers, breakdown lamps).
1.3 Certificate : CE
NB8-40J
General
1.1 Function : Protection of circuits against short-circuit currents, protection of circuits against overload currents, switch, isolation. NB8 -40J circuit-breakers are used in domestic installation, as well as in commercial and industry electrical distribution systems.
1.2 Selection : Technical data of the network at the point considered: short-circuit current at the circuit-breaker installation point, which must always be less than the breaking capacity of this device, network normal voltage.
Tripping curves:
B curve (3-5In) protection for people and big length cables in TN and IT systems.
C curve (5-10In) protection for resistive and inductive loads with low inrush current.
D curve(10-16In) protection for circuits which supply loads with high inrush current at the circuit closing
(LV/LV transformers, breakdown lamps)
1.3 Certificate : CE